Titanium Mixed Metal Oxide Coated,Platinum Water Heater Anode for ICCP of AO smith

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-11-16 07:47

  • Browse the number:

    155

Send an inquiries
Company Profile
Xi'an Taijin Industrial Electrochemical Technology Co.,Ltd
By certification [File Integrity]
Contact:

taijin(Mr.)  

Email:

Telephone:

Phone:

Area:

Beijing

Address:

NO.15 XiJin Road, Jingwei industrial Park, Xi'an City, Shaanxi, China

Website: http://www.taijinanodes.com/ http://www.vintagechinahirehertford.com/com/taijin/
Product details
Titanium Mixed Metal Oxide Coated,Platinum Water Heater Anode for ICCP of AO smith

Equipped with professional factory, Taijin Industrial is the biggest China manufacturer, supplier and producer of water heater anode. Our company can offer you corrpro vendor water heater anode rod, anode rod water heater, anode rods, anode rod replacement, water heating rod at competitive price.

                                                                                      TECHNICAL DATA SHEET
                                                     TAIJIN WATER HEATER ANODES FOR CATHODIC PROTECTION

TAIJIN MMO Water Heater Anode is manufactured using titanium substrate which meets ASTM B348 Grade 1 Standard and coated with Mixed Metal Oxides or Platinum on the external surface.

TAIJIN MMO Water Heater anode is used in water heater, water container, pre-polarization of steel structure in seawater, gas pipe, Anticorrosion of steel and iron structure where high resistant and electrolyte(soil and water) existed.

1.Structure:

A

200mm

400mm

B

200mm

400mm

C

2mm

3mm

Screw head

NPT3/4

G3/4

Diameter, length and working life all can be available as client's requirement.

2.Working parameter:

Current density < 2000A/m2
Working temperature: no more than 60℃
Chlorine-liberated potential <1.13V
Working environment: fresh water, brackish water
Reverse electrolysis frequency: 2 or 4 hours
Working life: 2-5years (as customer’s request)

Operation test:
Less than the temperature of 100 ℃,the operation current density 50A/m2,the working life time is more than 10 years.

3.Coating:

Mixed Ruthenium-Iridium oxide or Platinum